Home

blog about Charlotte Pipe Releases Guide on PVC D2729 Drain Pipe Specifications

I'm Online Chat Now
Company Blog
Charlotte Pipe Releases Guide on PVC D2729 Drain Pipe Specifications
Latest company news about Charlotte Pipe Releases Guide on PVC D2729 Drain Pipe Specifications

Selecting improper drainage pipe materials can lead to project delays and safety hazards. PVC D2729 drainage pipes are a common choice, but how much do you really know about their performance characteristics, installation requirements, and potential risks? This analysis examines Charlotte Pipe's PVC D2729 drainage pipe products through a data-driven lens to support informed decision-making.

1. Product Overview: Technical Specifications of PVC D2729

Charlotte Pipe, a leading North American pipe manufacturer, produces PVC D2729 drainage pipes specifically designed for drainage applications in environments with temperatures not exceeding 140°F (60°C). These ASTM D2729-compliant pipes are manufactured in the United States, ensuring quality traceability.

1.1 Materials and Standards

The pipes use virgin rigid PVC (polyvinyl chloride) material meeting ASTM D1784 Standard's 12454 classification. This grade specifies critical performance metrics including impact resistance, tensile strength, and modulus - ensuring sufficient durability for drainage system demands.

1.2 Dimensions and Physical Properties

All dimensional and physical properties strictly comply with ASTM D2729 requirements. This standardization guarantees consistent pipe diameters, wall thicknesses, lengths, compressive strength, and ring stiffness - factors directly impacting load-bearing capacity, deformation resistance, and service life.

2. Installation Guidelines: Ensuring Long-Term System Performance

Proper installation is critical for PVC D2729 drainage system longevity. Charlotte Pipe provides detailed installation instructions that must be followed in conjunction with local plumbing, fire, and building codes.

2.1 Underground Installation

Buried pipe installations require adherence to ASTM D2321 and ASTM F1668 standards, which specify trench excavation, backfill material selection, and compaction requirements. Special attention must be paid to avoiding sharp rocks or corrosive substances in backfill materials that could damage pipes.

2.2 Solvent Welding

The standard connection method uses ASTM F656-compliant primer and ASTM D2564-compliant solvent cement. The two-step process involves surface preparation with primer followed by solvent cement application. Properly welded joints achieve necessary strength and leak resistance.

2.3 Chemical Compatibility

PVC materials show sensitivity to certain chemicals. Installers must prevent contact with incompatible substances including fireproofing materials, thread sealants, plasticized vinyl products, or corrosive chemicals that could degrade pipe integrity.

2.4 Hydrostatic Testing

Post-installation pressure testing verifies system integrity. Test pressures should match design specifications with sustained duration. Critical safety note: compressed air or gas testing is strictly prohibited due to explosion risks.

3. Product Specifications: Performance Parameters by Size

Charlotte Pipe offers PVC D2729 in multiple sizes including 3-inch, 4-inch, and 6-inch diameters. The table below details key specifications for engineering reference:

PART NO. NOM. SIZE (IN.) UPC # QTY. PER SKID AVG. OD (IN.) MIN. WALL (IN.) BELL DEPTH (IN.) WT. PER 100 FT. (LBS.)
PVC 30030 3" x 10' 10903 1130' 3.250 0.070 3.00 52.8
PVC 30040 4" x 10' 10905 670' 4.215 0.075 3.50 70.4
PVC 30060 6" x 10' 15149 330' 6.275 0.100 4.00 129.0
PVC 30030P 3" x 10' 11814 1130' 3.250 0.070 3.00 52.8
PVC 30040P 4" x 10' 11815 670' 4.215 0.075 3.50 70.4

Note: PVC30030P and PVC30040P denote perforated pipes for specialized drainage applications.

4. Perforated Pipes: Specialized Drainage Solutions

Charlotte Pipe's perforated PVC D2729 pipes feature uniformly spaced holes for groundwater collection and discharge, commonly used in drainage, irrigation, and soil amendment systems.

4.1 Perforation Specifications

Standard perforations use 1/2-inch (12.7mm) diameter holes spaced 5 inches (127mm) apart in two rows parallel to the pipe axis with 120° angular separation. This configuration ensures effective groundwater collection from all directions.

5. Risk Considerations and Precautions

While PVC D2729 pipes offer numerous advantages, users should be aware of these critical considerations:

  • Temperature limitations: PVC materials have limited heat resistance - prolonged high-temperature exposure may cause deformation or degradation
  • Chemical corrosion: Certain substances can corrode PVC materials, requiring careful compatibility assessment
  • UV degradation: Outdoor installations require UV protection measures like protective coatings
  • Improper installation: Deviations from manufacturer guidelines may cause leaks, deformation, or pipe failure
  • Static accumulation: PVC's high resistivity requires electrostatic discharge precautions in flammable environments
6. Conclusion

PVC D2729 drainage pipes represent an economical, durable, and installation-friendly solution. Charlotte Pipe's manufacturing standards ensure quality and performance consistency. However, successful implementation requires careful consideration of application suitability, proper installation techniques, and risk mitigation strategies to ensure long-term system reliability.